1. State regulations mandate that a backflow assembly must be:

2 / 50

2. Which of the following connections is deemed inappropriate?

3 / 50

3. In ideal conditions with a perfect vacuum at sea level, water is drawn into a 40-foot vertical pipe. What is the pressure in the pipe above the water surface?

4 / 50

4. Where can you find a procedure for conducting a cross-connection test?

5 / 50

5. What regulates recycled water and its approved uses?

6 / 50

6. According to the Uniform Plumbing Code, what is the minimum distribution pressure required at the point of delivery?

7 / 50

7. What is the required number of test cocks for an approved DC assembly?

8 / 50

8. According to the Uniform Plumbing Code (UPC), how should an RP assembly be installed?

9 / 50

9. What is the purpose of installing a backflow assembly at the service connection?

10 / 50

10. Backsiphonage is classified as which of the following?

11 / 50

11. What type of backflow may occur due to an indirect cross-connection?

12 / 50

12. Who is responsible for supplying an approved water supply to the public, whether a public or private entity?

13 / 50

13. Once water has passed through the water connection from the public potable water system and is no longer under the control of the Water Purveyor/Supplier, what is it considered?

14 / 50

14. The recommended type of backflow assembly installation to protect the water system from a  plant using radioactive material is:

15 / 50

15. Which recognized organization approves backflow assemblies based on the successful completion of both field and laboratory evaluation?

16 / 50

16. What is the term for a water service where water passing through a meter supplies both domestic and fire water to a facility?

17 / 50

17. According to industry guidelines and standards, what is the highest quality level of recycled water?

18 / 50

18. How is a pollutant categorized?

19 / 50

19. What color is used to identify new piping installed for delivering recycled water?

20 / 50

20. How should protection from freezing for backflow assemblies be ensured, as per regulations?

21 / 50

21. In the case of air-gaps, what is the term used for the minimum cross-sectional area at the seat of the control valve supply pipe or tubing that feeds the device or outlet?

22 / 50

22. When correctly installing an AVB on an irrigation system, what condition allows the downstream piping to be elevated above the AVB?

23 / 50

23. During a cross-connection survey, which of the following would have the highest priority for backflow protection?

24 / 50

24. According to the UPC, what is the required distance for an air-gap separation on a 2-inch spout, situated 4 inches from the side wall and 2 inches from the back wall?

25 / 50

25. What is the status of hose bibs on recycled water systems?

26 / 50

26. What is the purpose of installing a DC detector assembly on a fire sprinkler system?

27 / 50

27. Who is responsible for establishing a list of certified backflow assembly testers?

28 / 50

28. What does the term "Air Gap Separation" refer to?

29 / 50

29. Where is the recommended location to install a DC assembly for service isolation?

30 / 50

30. What is the responsibility of the water user when there's an on-site backflow prevention assembly installed? They must ensure a competent inspection is conducted at least:

31 / 50

31. According to the UPC, what is the appropriate method of correcting a cross-connection to piping containing sewage?

32 / 50

32. If water to a critical service cannot be shut off, even momentarily, what should be done with the backflow assembly?

33 / 50

33. Where should backflow assemblies not be installed?

34 / 50

34. Who has the responsibility and liability for protecting the potable water distribution system?

35 / 50

35. If a customer possesses an unapproved "auxiliary" water supply on the premises, with no known connections to the distribution system, what is the minimum protection normally required by the Water Purveyor/Supplier for the distribution system?

36 / 50

36. Which elements of public relations are significant for the specialist?

37 / 50

37. What is required in a cross-connection control program?

38 / 50

38. Maps and as-built drawings of the consumer’s potable water system:

39 / 50

39. As a general rule, the appropriate type of backflow prevention assembly should be based on:

40 / 50

40. When should the initial test of a backflow assembly be conducted?

41 / 50

41. Which of the following situations would significantly contribute to water backflow through a cross-connection?

42 / 50

42. What is the minimum clearance required for installing a RP backflow assembly?

43 / 50

43. Who is responsible for establishing a list of approved backflow assemblies for protecting a municipal water supply system?

44 / 50

44. What can a water-line connected to a process steam-line (without chemicals) be protected by?

45 / 50

45. What components must be included in an approved Backflow Prevention Assembly?

46 / 50

46. Steam boilers are classified as high hazard due to:

47 / 50

47. Which of the following types of cross-connections are considered unauthorized?

48 / 50

48. What temperature designation should an atmospheric vacuum breaker rated for cold-water usage have?

49 / 50

49. What term describes a situation where two or more water services are provided to a single property?

50 / 50

50. In the scenario where a customer possesses a polluted "auxiliary" water supply on their premises with no known connections to the distribution system, what is typically the minimum requirement set by the Water Purveyor/Supplier to safeguard the distribution system?